6. Once the system displays Idle, press Maintenance>System>Test Parts then select the test_XY_cal part. 7. When part is completed, remove from printer and let cool for five min- utes. 8. Locate the filled circle, this indicates the front of the substrate, see Figure 323 Figure 323: Locating the Filled Circle (B) 9. Using a digital caliper, measure and record the diameter of circle B along the center line between A and C, see Figure 324 NOTE: Reference letters are not actually “printed” on the part. If needed, use the Part Measurement Equations sheet to record the values. See “Part Measurement Equations” on page 359. Figure 324: Measuring diameter of B 10.
Next measure and record the distance from the outside edges of circle A and B, see Figure 325 Ensure that the caliper is not seated on the small bump of circle A. -344