HP — Performing part based calibration for HP Designjet 3D from the Service Calibration menu (Firmware version 9.1 or newer)

Figure 325: Measuring distance from outside edges of A and B 11. Next measure and record the distance from the outside edges of circle B and C, see Figure 326 Ensure that the caliper is not seated on the small bump of circle C. Figure 326: Measuring distance from outside edges of B and C 12. Add the lengths derived from steps 10 and 11 (A-B and B-C) and then subtract the width of circle B. Record this total as “GFront” 13. Measure and record the distance from the outside edges of circles E and F. Ensure the caliper is not seated on the small bump of circle E. See Fig- ure 327 Figure 327: Measuring distances from outside edges of E and F 14.

Measure and record the distance from the outside edges of circles F and G. Ensure the caliper is not seated on the small bump of circle G. See Figure 328 -345