HP — Performing part based calibration for HP Designjet 3D with the HP Designjet 3D Diagnostic Software

Figure 351: Measuring distances from outside edges of D and G 26. Measure and record the diameter of circle D along the center line between A and G. See Figure 352 Figure 352: Measuring diameter of circle D 27. Add the lengths derived from steps 24 and 25 (A-D and D-G) and then subtract the width of circle D derived from step 26. Record this total as “Left Front” 28. Open HP Designjet 3D Diagnostic Software and select the Current Mod- eler from the pull down menu. 29. Open the Open Gantry Calibration Dialog box in HP Designjet 3D Diagnostic Software. 30. In the Part Calibration section, there are six boxes: LEFT, RIGHT, FRONT, REAR, LEFT FRONT and LEFT REAR.

Enter the measurements in the appropriate box. 31. Once the values have been entered, click on the green check mark. 32. Toggle the system power switch to accept the new values. 33. Run a test part to verify system is operating correctly. -358