Performing part based calibration for HP Designjet Color 3D from the Service Calibration menu (Firmware version 9.1 or newer) 1. While the printer is at Idle , enter standby mode by pressing the Standby... button. 2. Enter the Service Calibration menu by pressing the following button sequence on the display panel: 3,2,3,3,1 . See Figure 354. Figure 354: Service Calibration button sequence Button 0 Button 1 Button 2 Button 3 4. The printer will ask “Do you want to zero settings and reboot?” Press Yes . 3. Press the Reset Part Based Calibration button. 5. Reboot the printer. 6. Once the system displays Idle, press Maintenance>System>Test Parts then select the test_XY_cal part. 7.
When part is completed, remove from printer and let cool for five min- utes. 8. Locate the filled circle, this indicates the front of the substrate, see Figure 355 -360