HP — Verify Liquefier Alignment

F. Position the Liquefier Alignment Rod so that the stepped portion is flush with the top of the Heater Block. G. Tighten the Heater Block Clamp screws. CAUTION: Use care when moving the Toggle Bar. Forcing the bar, or applying too much pressure, will damage the Liquefier Alignment Rod and cause a misalignment of the Liquefier Tubes with the filament path. H. Move the Toggle Bar to the full Left position. I. Tighten the lower Heater Block Mount screw until it is snug. J. Tighten the upper Heater Block Mount screw until it is snug. K. Tighten the lower and upper Heater Block Mount screws to final torque. NOTE: Make sure that the Heater Block does not move while tightening the mount screws. L.

Move the Toggle Bar to the right until the Drive Wheel no longer contacts the Liquefier Alignment Rod. M. Loosen the Heater Block Clamp screws and remove the Liquefier Alignment Rod. 2. Left (Support) side: A. Repeat step 1 above - except reverse the Toggle Bar positions. Verify Liquefier Alignment This procedure makes sure that the Liquefier Tubes are properly aligned with the filament path. This procedure must be performed after “Liquefier Alignment” on page 397. is performed. 1. Install the Heat Shield - install and tighten the 2 retaining screws - make sure the teflon washers are installed between the Heat Shield tabs and the Translator. 2.

Install the new Liquefier Tips ( Figure 413 ) A. You must identify the correct replacement tip. The uPrint uses two tip types. You must make sure a SUPPORT tip is used on the LEFT side of the head assembly. A MODEL tip must be used on the RIGHT side of the head assembly. The Model tip comes in a Red capped container. The Support tip comes in a Black capped container. -398 CAUTION: Model and SOLUBLE support tips are different. The correct tip must be installed in the correct side.