HP — Liquefier Alignment

F. If the tension is not correct remove the Idler Wheel Tension Adjust screw (5/64” Allen), apply LocTite 222 to the screw threads, and install the screw. G. Adjust the screw to obtain a light drag on .003 inch feeler gauge when it is positioned between the Drive Wheel and the Idler Wheel. H. Check the tension with the .005 inch feeler gauge as above. I. Continue to adjust the screw until the prescribed tension is obtained. J. When adjustment is complete, place the Toggle Bar in the Neutral position, and remove all feeler gauges. K. Place the Toggle Bar in the full Right position and spin the Idler Wheel by hand. The Idler Wheel should spin freely without drag.

If drag is present, re-check adjustments. Figure 412: Idler Wheel Adjustment - Left Side Left side Idler Wheel Tension Adjust screw. For SST: Use .003 inch and .005 inch feeler gauges (shim stock) to check clearance. Liquefier Alignment This aligns the Liquefier Tubes with the filament path. 1. Right (Model) side: A. Move the Toggle Bar to the full Right position. B. Make sure the right side Heater Block Mount and Clamp screws are loose. C. Make sure that the Liquefier Alignment Rod is straight. Roll the Rod along a flat surface to check for bends. Straighten as necessary. D. Insert the Liquefier Alignment Rod from the bottom of the right side heater block - small end first. E.

Push the Alignment Rod up into the Main Pivot Block. -397