HP — Tera Term Commands

4. ss = Switch Status The ss diagnostic message reports system status. The controller outputs a report on optical and mechanical switches to the terminal window. Use this for checking: • Printer Gender (sent either wrong system software or .CAL file to printer). • Motor gear ratio (if the system does not home correctly, the gear ratio could be changed from cable table to belt table). • Head temp set point (with MaracaEX you can change the temp to not match system software specification, causing errors). • System Software version check. Figure 441: Switch status -436 Average surface: This is the Average distance in inches between the sub- strate and the Z BOT sensor.

The machine is looking for the planarity of the substrate, if the substrate is not flat, then the machine will not home. Lowest surface: This is the lowest distance in inches between the sub- strate and the Z BOT sensor. SR64K type Z-Stage detected means, that the Z-Stage has a Gear Ratio of 64000 microsteps per inch. This indicates either a three leadscrew Z-Stage or a single leadscrew Z-Stage.