HP — Tera Term Commands

3. fz = Find Z home This command determines the Z axis home position. This position is determined by the modeling base that is installed in the system. The find home command must be executed before this command will work. Used to check for obstructions causing Z sensor errors. Also good for checking the Z foam sensor touch down points ( Z stage going bad). Example: fz The values, which are displayed, are explained below, see Figure 440 Figure 440: Find Z Home -435 Actual Travel Limits: This is the distance between the BOT (Begin Of Travel) and EOT (End Of Travel) Sensors in inches. Set origin to:

This gives an offset to the BOT sensors so the machine is not moving into the sensors during a build. Surface at touch point: This is the distance in inches from the surface of the substrate to the Z BOT sensor.