8. tm = monitors temperatures This command displays temperature information for the model Liquefier, support liquefier, and chamber heater. Use this command if you experience temperature problems with the head. Check if the model and support temperature reach the set point and if the temperature is stable once it reaches the set point temperature. Check if the PWM value varies instead of switching on and off. If the PWM switches on and off, then the T/C board might be the root cause. (see also 14:67 error in the Troubleshooting Guide) Used for troubleshooting TC errors. Enter maintenance mode with the head at full temp and wiggle the umbilical cable to check for wire issue.
Also to check if the PWM works to system specifications (you should see a slow change in PWM like 20 to 30 to 40 not 10 to 100). The information is displayed on a single line in the following format: MM/DD/YY HH:MM:SS: m / / / s / / / c / / Parameter Description Current temperature Current temperature setpoint Pulse Width Modulation status Temperature setback (1 = Active, 0 = Inactive) m Model s Support c Chamber Figure 445: Monitor temperatures Examples:
Command Description tm Single print of the current temperatures tm 1 One line displaying temperatures updating every second tm 0 Turns off temperature updating every second rt XXXX 1 tm Prints the temperature continually the number of times repre- sented by XXXX 9. mz = Move Z -440