HiPhi — 7.10.2.3 Diagnostics for the 3SK2 family

Devices in the control panel and the machine environment 7.10 Control circuit - safety relays 7.10.2.2 Expansion units for the 3SK1 Advanced family Input expansion If more than one sensor is required, it is only necessary to provide an input expansion rather than additional basic units. The 24 V power supply supplies up to six components with voltage – whether basic units or input or output expansions. It covers all conventional global control voltages from 110 to 240 V AC/DC. This means that the safety relays can be deployed almost anywhere in the world.

7.10.2.3 Diagnostics for the 3SK2 family Diagnostics display 3RK3611-3AA00 The diagnostic display 3RK3611-3AA00 provides assistance with troubleshooting in the event of outages. When combined with the 3SK2 device, it immediately indicates which sensor has operated. It also helps to locate plant faults. This saves time and costs. The diagnostics display can also be used to read out and save configuring data from the 3SK2 devices. This also helps to save time when a device is replaced. Configuring data can also be copied without a PC/PG. This is particularly useful for the manufacture of standard machines.

Figure 7-37 Diagnostics display 3RK3611-3AA00 See also Control circuit - signaling columns (Page 293) Control Panels compliant with IEC Standards and European Directives Reference Manual, 10/2017, A5E38284819002A/RS-AB/002 281