Control engineering - definition of terms and fundamental principles 5.5 Degree of protection of enclosures Examples IP54 5 = dust-protected. Ingress of dust is not totally prevented, but dust shall not penetrate in a quantity to interfere with satisfactory operation of the apparatus or to impair safety. 4 = protected against splashing water. Water splashed against the enclosure from any direction shall have no harmful effects. This means that water may enter the enclosure, but it shall not cause any damage or safety hazards. IPXXB Protection against ingress of solid foreign objects and/or water is not required.
The additional letter indicates, however, that access to hazardous parts is protected for incidental contact with fingers. This is generally referred to as "finger-safe". Verification Enclosures shall be tested in specially equipped laboratories to verify that they comply with the requirements for a particular degree of protection. Recommendation Enclosures that have already been tested in accordance with IEC 60529, (e.g. 8MF, ALPHA 3200, SIVACON) should be used. Minimum degree of protection IEC 60204-1 → IP22 IEC 61439-1 → IP2X the front of an open switchgear and controlgear assembly → IPXXB Installation of command and signaling devices in the door of a control panel, e.g. with IP54.
In order to maintain the degree of protection of the panel, the two numerals in the degree of protection of the equipment shall be equal to or higher than the numerals of the panel. Examples: Panel IP54 and pushbutton IP44 → not possible because degree of protection of panel would then only be IP44 Panel IP54 and pushbutton IP54 → OK, overall degree of protection IP54 Panel IP54 and pushbutton IP65 → OK, overall degree of protection IP54 Control Panels compliant with IEC Standards and European Directives Reference Manual, 10/2017, A5E38284819002A/RS-AB/002 53