Chapter 7: Maintenance Warning: Axis may fall due to gravity Figure 7-3. Brake Release/Gravity Label This label is located next to the brake release button and brake release button label. Informative Labels l Brake Release Label, 18265-000 This label identifies the brake release button on the underside of the Hornet 565. It is a ring that surrounds the brake release button. 7.4 Checking Safety Systems These tests should be performed every six months. NOTE: Operating any of the following switches or buttons must disable high power. If any of the tests fail, repairs must be made before the robot is put back into operation. 1. Test operation of:
l E-Stop button on front panel l Auto/Manual switch on front panel If the optional pendant is present: l E-Stop button on pendant l Enabling switch on pendant (Manual mode only) 2. Test operation of any user-supplied E-Stop buttons. 3. Test operation of barrier interlocks, etc. 7.5 Checking Robot Mounting Bolts Check the tightness of the base mounting bolts after the first week, and then every 3 months. Refer to the following table for torque specifications. Table 7-5. Mounting Bolt Torque Specifications Hornet 565 Robot User's Guide, 14608-000 Rev C Page 104 of 156 Standard Size Torque Metric M12-1.75 61 N·m (45 ft-lb)