omron — 7.6 Checking for Gear Drive Oil Leakage

Chapter 7: Maintenance 7.6 Checking for Gear Drive Oil Leakage NOTE : Gear drive inspection and fan operation inspection require removal of the same robot parts, and have the same schedules. You will probably want to perform these two inspections at the same time. NOTE : The inner arm motor plugs are not used for this inspection because they can- not be removed without destroying them. WARNING: Remove all power to the robot before opening the eAIB chassis. The Hornet 565 uses gear drives, which use oil in their components for lubrication. Peri- odically inspect the robot for signs of oil on and around the gear drives. To check the J1 and J2 gear drives: 1.

Remove all power to the robot before starting this check. 2. Wait for the motors to cool before performing this check. Lock out and tag out AC power. 3. Remove the eAIB. See Replacing the eAIB Chassis on page 121. You do not need to disconnect the cables to the eAIB. WARNING: Do not remove the encoder cable connectors from their sockets on the motors. If they are removed, the calibration data will be lost, requiring factory recalibration. 4. Check for oil inside the base of the robot. l Look through the venting slots under each motor for oil leakage. l Feel the bottom of the motors with your finger through the venting slots. 5.

Check the outside of the motors and gear drives for any signs of oil. 6. Contact Omron Adept Technologies, Inc. if you find any signs of oil in these areas. If you aren’t going to check the operation of the motor fans: 7. Re-install the eAIB. See Installing a New eAIB Chassis on page 124. To check the J3 gear drive: 1. Remove the four M4 hex-head bolts holding the Status Display panel. l Retain the bolts for re-installation. l These bolts were installed with Loctite 222. Hornet 565 Robot User's Guide, 14608-000 Rev C Page 105 of 156