omron — 7.7 Checking Fan Operation

Chapter 7: Maintenance 2. Remove but do not disconnect the Status Display panel. Retain the Status Display panel and gasket for re-installation. 3. Check the outside of the motor and gear drive for any sign of oil. Contact Omron Adept Technologies, Inc. if you find any sign of oil in these areas. 4. Re-install the Status Display panel with the four M4 bolts previously removed. l Apply Loctite 222 in each bolt hole, not on the bolts themselves. l Ensure that the Status Display panel gasket is in place between the panel and the l Torque the bolts to 1.1 N·m (10 in-lb). robot body. 7.7 Checking Fan Operation The motor fans are PWM controlled.

This check needs to be done with 24 VDC to the robot ON. NOTE : The fans are not field-replaceable. In the unlikely event that a fan fails, it needs to be replaced at the factory. Verify that all fans operate: Fans for J1 and J2 motors: 1. Remove the eAIB. See Replacing the eAIB Chassis on page 121. 2. Toggle power to the eAIB. You do not need to disconnect the cables to the eAIB. Motor fans run for about 1 minute before shutting off. (If the robot is hot, they will con- tinue to run.) 3. Verify that J1 and J2 motor fans are running by looking through the eAIB opening. 4. Re-install the eAIB. Installing a New eAIB Chassis on page 124. Fan for J3 motor:

(this cannot be seen through the eAIB opening) 1. Remove the four M4 hex-head bolts holding the Status Display panel. l Retain the bolts for re-installation. l These bolts were installed with Loctite 222. 2. Remove but do not disconnect the Status Display panel. Retain the Status Display panel and gasket for re-installation. 3. Toggle power to the eAIB. Hornet 565 Robot User's Guide, 14608-000 Rev C Page 106 of 156