2686A/D - FAULTS WITH ERROR NUMBERS (Con’t) 2686D ERROR 12, paper not feeding correctly from both I/P trays, it “Judders”, then Error12 occurs. Also a BLANK page is emitted from the printer. Traced to bad “Lid Switch” ie “DOOR OPEN”. (Loss of +24v). ERROR’s 20,21, 22& 40 Error 20 (memory overflow) and Error 21 (print ovemm) Usually caused by software due to the following CPU~ost sent to much Data to 2686. To clear press continue. Error 21...The formatter cannot catch-up with print the print engine. Error 22 (Buffer Overflow) and Error 40 (line error)., Usually caused by system configuration problems i.e. Baud rate, parity, 7[8 bits, Xofioff/DTR, Normal settings:
Baud rate -9600 Parity - None Bits -8 bits H’stie - XotiXoff IN GENERAL, REPLACING IIF WILL NOT CORJU?CTERROR ‘S 20.21, 22& 40. See Servke Note 2686A-9 ERROR 50 Hard Fault (S= note on below) Normally caused by the following in order of preference: L The 470hm resistor on Fuser Safe@ PCA blown. (obtain 1/4 watt local~) or HP PIN is FF1-3872-OOOCN.(See Sfl 2686A-10). 2. Fuser Saf@ PCA. 3. AC Controller PCA.(new @pe has -040CN suffm). 4. Vibration in @anspo&g the 2686 causes Fuser Bulb to rotate glass protrusion on fuser bulb to point towards thermistor. 5. Fuser Bulb, should read 9/10 ohms. (known to blow at 11 ohms). 6. Faulty or Dirty Thermistor.
Z Bad connections on the Fuser Saf@ or AC Controller PCA ‘s. 8. Repbce The in Power Module assy. 9. Faul@ DC Power SuppfyMain Motor PCA. 10. If faultpersists replace Fuser Safety, AC ControUer and Trtic together. 11. Check z~2686 is conjiguredfor 240volts? N’otc Due to error messages being retained in memory for some time afte power down it can fool the Service CE into believing the assy just replaced did not resolve the problem. Either do one of two things: (Continued nextpage) 2-4