26~6AM - FAIJ1 ,TS WITH F.RROR NITMRW,RS (Pnn$tl -. --.-— ------- .----- -. =.- -.. .w...__=.- ,_w-. 1) Leave 2686 powered down for at least 10 minutes. 2) Alternatively, gain access to the DC Controller PCA whilst powered down and put a short across R250, near C235. Also see Service Note~ 2686N/AU-4 or 2686A-3 and 2686~/AU-11 or 2686A-10 INTERMITTENT ERROR 50 Possible causes- 1. Nohey AC Mains Power Supply. The 2686A’s are more susceptabfe to AC mains disturbances than perhaps other equipment ConnectAC Mains Monitor. Check quality of mains supply. 2. InstallAC Controller who’s Pm ends in -040CN Suffa 3. Replace QI Triac. 4. Checkfor AC Voltages asper below: PS/W Motor PCA @om Transformer.
These are:- 33, 12, 21volts on J501 connetir. 5, Check z~2686 is conjiguredfor 240v. 6. Noisv AC mains, instaU mains monitor. Z See 2686A-10 Service Note. 8. Replace DC PS~ain Motir PCA. 9. Replace DC Controller PCA. ERROR 52? Replace ~ PCA ERROR 53? Replace Laser unit E~OR 60 & 61. Both these errors can be wused byfaulty W PCA ‘s. ERRORS 63, 65& 67 Normally caused by LT PCA. ERROR 67 Cm be caused by very cold environments i.e temperatures in office maybe falling very low over night. May give this problem only first thing in the morning, there on after will be OK all day.
ERROR 60, 65& 67 Can be caused by atteinptkag to put to many fonts on one page MISCELLANEOUS Especially Error’s 60,63 and 67 may be caused by ERROR’s 6X. loose ubfing. If the cable are not securely fixed down the printer may exhibit these problems. 2-5