Data Logging and Display Runtime Interface When enabled, some embedded interfaces can help the user to interact with the Trend Control during runtime. This section describes these interfaces: • Toolbar : The commands available in the embedded Toolbar are described in the following table: Page 254 InduSoft Web Studio Area / Element Name Description Name of the screen which must be launched when the user triggers a command to modify or insert a new pen to the object during runtime. Point Number Point number (from the Points dialog), indicating the point associated to the pen that will be inserted or modified during runtime.
Add Indicator Flag that indicates that the user triggered an action to insert a new pen (value 1) instead of modifying a pen that is already been visualized (value 0). Export to File Trigger When the tag configured in this field changes value (e.g., toggles), the current state of the trend control is exported to an image file. The toolbar and scroll bar are not included. The legend and time display are included only if the trend control is configured to show them. File Name The file path and name of the exported file. If no path is specified, then the file is saved in the project directory. If no extension is specified, then it is determined by Format. Tip:
You can specify a project tag in curly brackets (e.g., {tagname}), to programatically change the file name during runtime. Status The tag configured in this field receives status codes that indicate the success or failure of the export. Format The graphic format of the exported file. If Auto is selected, then the format is determined by the extension specified in File Name. If Auto is selected but no extension is specified, then the default format is BMP. Size The image file is exported at full size by default. However, you can specify the width and height (in pixels). Options VK (Virtual Keyboard) Virtual Keyboard type used for this object.
Ignore X Filter When this box is checked, the X Filter is ignored to avoid adding the WHERE or querying clause to the Data Sources. Enable translation Enable the external translation for the text displayed by this object. Auto Format When checked, decimal values in the Current, Cursor, Max, Min and Scale columns will be formatted according to the virtual table created by the SetDecimalPoints() function. Note: For the Auto Format to work, decimals formatting on the X-axis must be disabled — that is, the Decimals field in the Axes dialog must be left blank. Command Icon Description Activation Tag Run Sets the Trend to the Play Mode.
In this mode, the X axis is continuously updated (Online Mode). This option is disabled (grayed out) when the trend is already in Play Mode. 0 = Play Mode on 1 = Play Mode off Stop Sets the Trend to the Stop Mode. In this mode, the X axis is not continuously updated (History Mode), so the user can visualize history data in a frozen period of time. This option is disabled (grayed out) when the trend is already in Stop Mode. 0 = Stop Mode on 1 = Stop Mode off Period Launches an embedded dialog, where the user can modify the X axis scale main settings. When the Activation Tag changes value (e.g., toggles), this command is executed.
Window Zoom Allows the user to click on the Trend area and drag the cursor to select the area that must be visible when the cursor is released. This option is disabled (grayed out) when the Multiple Section option (for the Y scale) is active. Horizontal Zoom Allows the user to click on two points in the Trend area, defining the horizontal scale that must be available.