omron — Frequently Asked Questions

Troubleshooting parameters set by it are kept in the system until the project is shut down. So, most projects execute this function just once, after starting the project; • Execute the function SendEMail(strSubject,strMessage,strTO) and/or SendEMailExt(strSubject,strMessage,strTO,strCC,strBCC, strFile1,...,strFileN) each time that an email message must be sent. The main difference between both functions are listed in the next table: Q. The runtime task (TCP/IP, OPC, DDE, ODBC, etc) does not work. A. Make sure the runtime task is set to Automatic in the Execution Tasks dialog ( Tasks on the Home tab of the ribbon).

Select a runtime task that must be executed (for example, TCP/IP Server), click Startup , and then set it as Automatic . Q. The browser from the Thin Client does not display the screen and launches a warning message regarding ISSymbol.ocx. A. Make sure the runtime task is set to Automatic in the Execution Tasks dialog ( Tasks on the Home tab of the ribbon). Select a runtime task that must be executed (for example, TCP/IP Server), click Startup , and then set it as Automatic . Q. The browser of the Thin Client launches an error message missing the ISSymbol.ocx and does not display the screens from the Server. A.

ISSymbol.ocx is the ActiveX object used by the browser from the Thin Client to view the web pages. If the Thin Client is connected to the Internet, the ISSymbol.ocx control is automatically downloaded and registered in the Thin Client station. Otherwise, it's necessary to copy it to the \WinNT\System32 folder of the Thin Client station and register it manually. Once it is registered your browser will be able to see the pages. Note: Use the command regsvr32 ISSymbol32.ocx to register the ActiveX component in the Thin Client. Q. The screens are shown on the Thin Client (Browser); however, the data (tags values) are not read from the Server. A.

Make sure the parameter in the column Scope from the project tags database is set as Server instead of Local . The tags set as Server keep the same value in the Server and in the Thin Client (Browser). The tags set as Local have independent values in the Server and in the Thin Client (Browser). Caution: It's necessary to verify the project ( Verify on the Home tab of the ribbon) after modifying the tags settings. Otherwise, the changes will not be updated in the Web pages. Q. The "On Up" expressions configured in the Command animation are not executed. A.

The "On Up" expressions from the Command animation are not executed if the mouse pointer is dragged out the object area before releasing it. If the checkbox Release from the Command Object Properties window is enabled, the On Up expression is executed even if the mouse pointer is dragged out the object area before releasing it. Q. The Trend History does not work after adding or removing tags in the Trend worksheet. A. When a tag is inserted or removed FROM a Trend worksheet, the format of the history files ( *.hst ) is modified. The same .hst file cannot have two different formats; otherwise, the data will not be retrieved from it properly by the Trend object.

If you need to add or remove tags for history files, there are two valid procedures: Create a new Trend worksheet or delete the old *.hst files. Q. The value of indirect tags ( @ TagName ) is not shown in the Thin client program. InduSoft Web Studio Page 435 Characteristic SendEmail SendEmailExt Execution Synchronous Asynchronous Supports Subject text Y Y Supports Message text Y Y Supports TO addresses Y Y Supports CC addresses N Y Supports BCC addresses N Y Supports attached files N Y