inductive and they cause problems with any output devices. The only other output consideration is if C2 is required. The basic function of C2 is to fill in the gaps of an AC input signal and keep the output in it’s active state during the time an AC signal is at a low level. The larger the value of C2 the bigger the gap can be and the output will not change. It does this by charging to the peak voltage of the signal and keeping a high level on the base of Q1, and therefore keeping Q1 turned on, for the short time the signal is low. After the input signal is removed for more than a few input cycles, C2 will discharge and Q1 will turn off, changing the state of the output.
This delay can cause problems with very short input pulses and will delay the time it takes for the output to respond to changes in the input. Because of this it may be desirable to not install C2 unless the output is required to provide a solid output for an AC input signal. For example if you are monitoring the AC line. The value indicated in the schematic and supplied with your OM2 should work for most AC input signals with a frequency from 50Hz or more. It is possible you may need to change it’s value due to your circuit requirements.
If you enjoyed this Ramsey product, there are plenty more to choose from in our catalog - visit our website at http://www.ramseyelectronics.com or call today! OM2 20