Victron Energy · Inverter Smart 230 V, new models · 2 pp.

Victron Energy Inverter Smart 230 V, new models

Related manuals

Document text

Bluetooth built-in: fully configurable with a tablet or smartphone Low battery voltage alarm Low battery voltage cut-off and restart levels Dynamic cut-off: load dependent cut-off level Output voltage: 210 – 245 V Frequency: 50 Hz or 60 Hz ECO mode on/off and ECO mode sense level Alarm relay Monitoring: In- and output voltage, load and alarms VE.Direct communication port The VE.Direct port can be connected to a computer (VE.Direct to USB interface cable needed) to configure and monitor the same parameters. Proven reliability The full bridge plus toroidal transformer topology has proven its reliability over many years.

The inverters are short circuit proof and protected against overheating, whether due to overload or high ambient temperature. High start-up power Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools. ECO mode When in ECO mode, the inverter will switch to standby when the load decreases below a preset value. Once in standby the inverter will switch on for a short period every 2,5 seconds (adjustable). If the load exceeds the preset level, the inverter will remain on. Remote on/off A remote on/off switch or relay contact can be connected to a two pole connector.

Alternatively, the H terminal (left) of the two pole connector can be switched to battery plus, or the L terminal (right) of the two pole connector can be switched to battery minus (or the chassis of a vehicle, for example). LED diagnosis Please see manual for a description. To transfer the load to another AC source: the automatic transfer switch For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features a very short switchover time (less than 20 milliseconds) so that computers and other electronic equipment will continue to operate without disruption. Alternatively use a MultiPlus with built-in transfer switch.

Inverter Smart 24/2k5 Battery Charger Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands E-mail: sales@victronenergy.com www.victronenergy.com Inverter Smart 230 V, new models www.victronenergy.com Inverter

Page 1

Inverter Control This panel is intended for remote on/off control of all Inverters Smart units. BMV-712 Smart Battery Monitor The BMV Battery Monitor features an advanced microprocessor control system combined with high resolution measuring systems for battery voltage and charge/discharge current. Besides this, the software includes complex calculation algorithms, like Peukert’s formula, to exactly determine the state of charge of the battery. The BMV selectively displays battery voltage, current, consumed Ah or time to go. The monitor also stores a host of data regarding performance and use of the battery. VE.Direct to USB interface Connects to a USB port .

Ekrano GX or Cerbo GX Provides intuitive system control and monitoring and enables access to our free remote monitoring website: the VRM Online Portal. Bluetooth wireless communication Connects to a smart phone (both iOS and Android) . Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands E-mail: sales@victronenergy.com www.victronenergy.com Inverter Smart 230V 12/2k5 24/2k5 12/4k 24/4k Parallel and 3-phase operation No INVERTER Input voltage range 9.3 – 17 V 18.6 – 34 V Output Output voltage: 230 VAC ±2 % 50 Hz or 60 Hz ± 0.1 % (1) Cont.

output power at 25 ºC 2400 W 3700 W Time limited power 1 (cold start) 2500 W/2 hr 4000 W/2 hr Time limited power 2 (cold start) 3200 W/15 min 5000 W/15 min Cont. output power at 40 ºC 2200 W 3400 W Cont. output power at 65 ºC 1500 W 2300 W Peak power 4000 W/5s 6000 W/5s Dynamic (load dependent) DC low shut Dynamic cut-off, see https://www.victronenergy.com/live/ve.direct:phoenix-inverters-dynamic-cutoff down (fully configurable) Max.

efficiency 12/ 24 /48 V 92 / 94 % 94 / 94 % Zero load power 12 / 24 / 48 V 10 / 10 W 16 / 20 W Zero load power in ECO mode 1.3 / 1,6 W 2,5 / 2.6 W GENERAL Programmable relay (1) Yes Stop & start power ECO-mode adjustable Protection (2) a - g Bluetooth wireless communication For remote monitoring and system integration VE.Direct communication port For remote monitoring and system integration Remote on-off Yes Common Characteristics Operating temperature range: -40 to +65 ºC (fan assisted cooling) Humidity (non-condensing): max 95 % ENCLOSURE Common Characteristics Material & Colour: steel (blue RAL 5012; and black RAL 9017) Protection category:

IP21 Battery-connection M8 bolts 2+2 M8 bolts 230 VAC-connection Screw terminals Weight 13 kg 20 kg Dimensions (hxwxd) 509 x 219 x 125 mm 591 x 278 x 162 mm (12 V) 535 x 286 x 162 mm (24 V) 535 x 286 x 162 mm (24 V) STANDARDS Safety EN 60335-1 Emission Immunity EN 55014-1 / EN 55014-2/ EN-IEC 61000-6-1 / EN-IEC 61000-6-2 / EN-IEC 61000-6-3 Automotive Directive ECE R10-5 1) Programmable relay that can a.o. be set for general alarm, DC under voltage or genset start/stop function. AC rating: 230 V / 4 A DC rating: 4 A / 35 VDC, 1 A / 60 VDC 1) Programmable relay that can a.o. be set 2) Protection key:

a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) 230 VAC on inverter output g) input voltage ripple too high 2) Protection key: for general alarm, DC under voltage or a) output short circuit genset b) overload start/stop function. c) battery voltage too high AC rating: 230 V / 4 A d) battery voltage too low DC rating: 4 A / 35 VDC, 1 A / 60 VDC e) temperature too high f) 230 VAC on inverter output g) input voltage ripple too high

Page 2