8.3 Connecting Peripheral Devices 8.3 Connecting Peripheral Devices Figure 8.1 illustrates how the drive and motor connect together with various peripheral devices. • Refer to peripheral device option manual for detailed installation instructions.
Engineering Software Tools CX Drive Power Supply USB Copy Unit USB Copy Unit COM ERR YASKAWA JVOP-181 Line breaker (MCCB) To serial comm port Copy Verify Read LOCK Drive B1 B2 Leakage breaker AC reactor Option Unit Breaking resistor unit DC reactor Ground Input side noise filter S/L2 +2 +1 U/T1 V/T2 W/T3 R/L1 T/L3 Output side noise filter Motor Ground Figure 8.1 Connecting Peripheral Devices Peripheral Devices & Options 8 SIEP C710606 33A OYMC AC Drive – J1000 User Manual 151