Kuhnke · 1 стр.
Kuhnke 60.073 Series Pneumatic Pressure Switch
Related manuals
Document text
Email: sales@impulseautomation.co.uk Website: www.impulseautomation.co.uk Kuhnke Pressure Switch Adjustable Pressure Switch (PE Converter) Technical information Pressure range: Max.10 bar Temperature range: 0˚C...+60˚C Housing: Plastic body, aluminium base. Diaphragm: Viton IP rating: IP65 with plug and seal Switching rate: Hysterisis: Dimensional drawings 0,8 Switching diagram for 3 - 8 bar M4 PA (bar) 7 8 M3 6 1,8 5 3 4 2 1 Electrical switching power in DC range for types 60.073.XX.60 82 1 0 PE (bar) 0 3 5 7 2 4 6 8 PE: Pull-in pressure PA: Drop-off pressure Connection plug Order code: Z802 4,8 PA (bar) Switching diagram for 0.5 - 4 bar 73 3,5 4,0 3,0 Document No:
PS000 Revision 1 2,5 2,0 1,0 1,5 P 0.5 Pressure connections on subplate. 0,5 0 PE (bar) 0 1,5 2,5 3,5 1,0 2,0 3,0 4,0 Impulse Automation Limited United Kingdom Company Registration 665193 Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described. Symbol Description Switching range Ports Order code 1 12 3 2 Pressure switch max. switching current at 220V AC 100mA 0.5 - 4 bar M5 60.073.40.01 Pressure switch max. switching current at 220V AC 100mA 3 - 8 bar M5 60.073.80.01 Pressure switch max.
switching current at 220V AC 6A 3 - 8 bar M5 60.073.80.60 Switching power Resistance load Inductive load 3 1 2 max. 0 4 8 8 P min. 12V DC 6 A 6 A 24V DC 3 A 2 A 4,5 (3) 2 4,8 9 15 64 (3) 4,8 9 15 60V DC 1 A 0.5 A 110V DC 0.5 A 0.2 A 220V DC 0.25 A 0.1 A P E PA 56 47 5 47 5 5 P 6 10 P 20 52 58 70 P 20 52 58 P E PA