L-6534VW Operation Guide Maintenance B Clean the workbench. Dampen the polyester/nylon knit woven fabric with the alcohol for cleaning the rollers, and then wipe off any paper powder, dust, glue, and so on. When substrate is loaded, lift it up a little and wipe underneath. C Check that the cleaned workbench is not damp. D Clean the plate for the paper edge sensor. Dampen the polyester/nylon knit woven fabric with the alcohol for cleaning the rollers, and insert it between the plates for the paper edge sensor, and then move it to the left and right to wipe off any paper powder, dust, glue, and so on. If it is still dirty, remove the plate and clean there.
U “Paper edge sensor/Joint sensor” on page 314 E Remove slack from the substrate. F Close the top cover on the corona treater. G Add a check mark to the item you have inspected, and then go to the next item for inspection. When you have finished the inspection, press Finished . This completes this section. 265