EPSON — Ionizer/Foreign Substance Detection Roller

L-6534VW Operation Guide Maintenance J Replace the ionizer. Be careful not to catch the cables when you insert the ionizer back into the press, align the screw holes on the left and right and set it in place. K Secure the ionizer with the screws on the left and right. L Check that there are no tools or jigs left inside the press. c Important: Do not leave any foreign substances inside the press. Print quality may decline, or the head could break down. You need to replace the head if it breaks down. M Remove slack from the substrate. N Return the three nip levers, and then set nip rollers A and B, and the foreign substance detection roller.

If you are going to clean the drum next, go to the appropriate item without returning the nip levers. U “Drum” on page 299 O Close the top front cover on the press. P Add a check mark to the item you have inspected, and then go to the next item for inspection. When you have finished the inspection, press Finished . 293