EPSON — Curing unit 3

L-6534VW Operation Guide Maintenance B Open the lock lever on curing unit 3 by turning it to the right, and then slide curing unit 3 to the right. C Clean the light glass in curing unit 3. Put your hand into the gap and use the spatula to remove the ink deposits, before wiping it with the polyester/nylon knit woven fabric dampened with the liquid for ink cleaning. Repeat cleaning until you can run the spatula over the surface without catching any ink deposits. Note: ❏ Clean the light glass thoroughly into each corner. ❏ Do not leave any foreign substances on the light glass. Otherwise, print quality may decline. 303