L-6534VW Operation Guide Troubleshooting If the press stops due to an emergency stop or power failure After performing an emergency stop on the press, follow the steps below to restart the press. If the press stops unexpectedly due to a power failure or other malfunction, start from step 6. A When performing an emergency stop using the EMERGENCY STOP switch, turn the EMERGENCY STOP switch that was pressed to activate an emergency stop in the direction indicated by the arrow, and then press Power Off on the touch panel error screen. B If the covers are open, close them, and then set the switch on the press to P . When the UPS light turns off, wait for at least 10 seconds.
C Once the noise from the press stops, set the breaker to OFF . 363