EPSON — The print position shifts when replacing with the same type of substrate during a print job

L-6534VW Operation Guide FAQ Changing the tension value ❏ When replacing the substrate Change the tension setting in the Substrate Settings menu - Change Substrate step 2. ❏ After changing the substrate (when telescoping or an error occurs) Change the tension setting in the Substrate Settings menu - Change settings screen. The print position shifts when replacing with the same type of substrate during a print job A. If a roll end error occurs during a print job, the print position shifts when replacing the substrate from the Change Substrate screen. Follow the steps below without pressing change substrate on the Change Substrate screen.

A Press the Feed Ready switch on the press to release the tension in the substrate. 403 Problem What to do Telescoping occurs when rewinding the roll too slowly ❏ Increase the tension value for rewinding by 1.3 times the standard value. ❏ Since telescoping occurs easily in film that is 120 mm or narrower, be careful when removing from the rewinder axis. "Foreign substance detected on substrate path channel" is displayed on the error screen If there are wrinkles or creases in the substrate on the substrate path channel when unwinding, increase the tension value for unwinding by 1.3 times the standard value. Additionally, replace the paper core and wind the substrate.

"Tension in the unwinder side has fallen below the minimum value." is displayed on the error screen is displayed on the error screen See the following to raise the tension value for unwinding. ❏ When the value is below the standard value: Return to the standard value ❏ When the value is higher than the standard value: Increase by 5 N more than the current value "Tension in the rewinder side has fallen below the minimum value." is displayed on the error screen See the following to raise the tension value for rewinding. ❏ When the value is below the standard value: Return to the standard value ❏ When the value is higher than the standard value:

Increase by 5 N more than the current value "E-9" is displayed on the display of the corona treater control panel A corona roller is not rotating. See the following to raise the tension value for unwinding. ❏ When the value is below the standard value: Return to the standard value ❏ When the value is higher than the standard value: Increase by 5 N more than the current value Press the OFF switch on the corona treater control panel to cancel the error display on the corona treater control panel.