EPSON — When performing additional printing, the print position gradually shifts

L-6534VW Operation Guide FAQ C Check the print results, and then measure the amount of print position shift for additional printing on the base. When the label design for additional printing shifts to the left of the base, this is a negative value. a: Substrate feed direction b: Amount of gap to measure D Calculate the amount of adjustment from the checked drum temperature and the measured amount of shift in the print position. The following shows the calculation method. Correction value = amount of shift in the print position / (checked drum temperature [˚C] -25) E Select the eye mark alignment temperature correction factor according to the amount of correction that you calculated.

See the following table to select the correction value closest to the value you calculated, and then select the corresponding eye mark alignment temperature correction factor. 415 Correction value (mm/˚C) Align eye mark temp correction factor -0.05 -5 -0.04 -4 -0.03 -3 -0.02 -2 -0.01 -1 0 0 0.01 1 0.02 2 0.03 3