Lithium NG 12,8V battery manual 3.3.1. The Lynx Smart BMS NG The Lynx Smart BMS NG is used in medium to large systems that contain DC loads and AC loads via inverters or inverter/ chargers, for example, on yachts or recreational vehicles. This BMS is equipped with a contactor that disconnects the DC system, a “Load disconnect,” a “Charge disconnect,” a "pre-alarm" contact, and a battery monitor. In addition, it can be connected to a GX device and control compatible Victron Energy equipment via DVCC. In the event of low cell voltage, the BMS will send a “Load disconnect” signal to turn the load(s) off.
Before turning a load off, it will send a pre-alarm signal indicating imminent low cell voltage. In case of high cell voltage or low/high battery temperature, the BMS will send a “Charge disconnect” signal to turn the charger(s) off. If the batteries are even further discharged (or overcharged), the contactor will open, effectively disconnecting the DC system to protect the batteries. For more information, see the Lynx Smart BMS NG manual, which can be found on the Lynx Smart BMS product page .
Charger Load Lynx Smart BMS NG NG The Lynx Smart BMS NG NG - The Lynx Smart BMS NG will turn loads and chargers off via “load disconnect”, and “charge disconnect” signals and controls the inverter/charger via a GX device. Should the battery be discharged even further, the BMS will disconnect the battery from the DC system. 3.3.2. The smallBMS NG The smallBMS NG is equipped with a load disconnect, a charge disconnect and a pre-alarm contact. In the event of low cell voltage, the smallBMS NG will send a load disconnect signal to turn the load(s) off. Before turning the load off, it will send a pre-alarm signal indicating imminent low cell voltage.
In the event of high cell voltage or low or high battery temperature, the smallBMS NG will send a charge disconnect signal to turn the charger(s) off. For more information, see the smallBMS NG product page . Load Charger The smallBMS NG controls loads and chargers via load disconnect and charge disconnect signals The smallBMS NG System design and BMS selection guide Page 7