Victron Energy Lithium NG 12,8V — 3.5. Battery monitoring

Lithium NG 12,8V battery manual 3.4. Charging from an alternator Compared to lead-acid batteries, lithium batteries have a very low internal resistance and accept a much higher charging current. Special care must be taken to avoid overloading the alternator: 1. Ensure the alternator's current rating is at least twice the battery's capacity rating. For example, a 400A alternator can be safely connected to a 200Ah battery. 2. Use an alternator equipped with a temperature-controlled alternator regulator. This prevents the alternator from overheating. 3. Use a current-limiting device like a DC-DC charger or a DC-DC converter between the alternator and the starter battery.

For more information on charging lithium batteries with an alternator, see the Alternator lithium charging blog and video . 60A 200A 100Ah 100Ah Current limiting 60A device 100Ah Alternator charging 3.5. Battery monitoring Common battery parameters such as battery voltage, battery temperature, battery current and cell voltages can be read out via Bluetooth using the VictronConnect app via the BMS. If a GX device (with internet) is used in conjunction with a Lynx Smart BMS NG, the data will also be made available on the VRM portal.

If, for some reason, you use an additional battery monitor in the system, ensure that the following settings are made so that the calculation of the SoC and the charged and discharged energy is done correctly: Set the charge efficiency to 99% Set the Peukert exponent to 1.05 Also, ensure that the external battery monitor is powered from the load terminal of the BMS and not directly from the battery to prevent accidental battery discharge. For more information on battery monitors, see the Battery monitor product page . System design and BMS selection guide Page 9 Temperature- controlled regulator 100Ah