Lithium NG 51,2V battery manual 4.5.6. Battery banks consisting of different batteries When constructing a battery bank, ideally, all batteries should be of the same capacity, age and model. However, there are situations where this is impossible, such as when capacity needs to be expanded by adding more batteries or when a single battery in a battery bank needs to be replaced. In these cases, follow the guidelines in the table below. Due to old batteries having reduced capacity, connecting them in series with new batteries or connecting different capacity batteries in series will result in an imbalance between the batteries.
This imbalance will increase over time and cause an overall reduction in battery bank capacity. Theoretically, the battery with the lowest capacity would determine the overall capacity of a series string, but in reality, the overall series string capacity will reduce further over time. For example, if a 50Ah battery is connected in series with a 100Ah battery, the overall string capacity is 50Ah. But over time, the batteries become imbalanced, and when the imbalance has become, let's say, 10Ah, the overall battery capacity will be 50Ah-10Ah = 40Ah.
The cells of the fullest battery will have an overvoltage during charging, while they are not able to send the excess voltage to the other battery cells. The BMS will constantly interfere, resulting in the emptiest battery is being discharged too deeply and the fullest battery is being overcharged. Background information: 4.6. Connecting the BMS Each battery has two BMS cables with an M8 male and M8 female connector that need to be connected to the BMS. Female and male BMS connector BMS cables on either side or on one side Connected BMS connectors How to connect the cables: For a single battery, connect both cables directly to the BMS.
For a battery bank consisting of multiple batteries, interconnect each battery (daisy chain) and connect the first and last cable to the BMS. The batteries can be interconnected in any order. If the BMS is too far away for the cables to reach, use the optional extension cables. The extension cables are available as a pair and come in various lengths. For more information, see the extension cable product page . BMS BMS Single battery BMS connection Two battery BMS connection (with optional extension cables) BMS Multiple battery BMS connection Page 15 Installation Battery bank type Di fferent capacities allowed? Different ages allowed?
Parallel Yes Yes Series No1) Yes2) Series/parallel - within a series string No1) Yes2) Series/parallel - in case a whole series string is replaced or added Yes Yes 1) All batteries must have the same capacity rating and the same part number 2) The age difference should not exceed 3 years