Victron Energy Lithium NG 51,2V — 6.1.5. Battery very low terminal voltage

Lithium NG 51,2V battery manual 6.1.5. Battery very low terminal voltage If the battery is discharged too deeply, the voltage will fall well below 12V (24V). If the battery has a voltage of less than 10V (20V or 40V respectively for 24V and 48V batteries) or if one of the battery cells has a cell voltage below 2.5V, the battery will have permanent damage. This will invalidate the warranty. The lower the battery or cell voltage is, the more damage to the battery will be. You can try to recover the battery by using the below low-voltage recharge procedure.

Be aware that this is not a guaranteed process, recovery might be unsuccessful, and there is a realistic chance that the battery has permanent cell damage resulting in a moderate to severe capacity loss after the battery has been recovered. Charge procedure for recovery after low voltage event: This recovery charge procedure can only be performed on an individual battery. If the system contains multiple batteries, repeat this procedure for each individual battery. This process can be risky. A supervisor must be present at all times. 1. Set a charger or power supply to 13.8V (27.6V, 55.2V). 2.

In case any of the cell voltages is below 2.0V, charge the battery with 0.1A until the voltage of the lowest cell increases to 2.5V. A supervisor must monitor the battery and stop the charger as soon as the battery is getting hot or bulging. If this is the case, the battery is unrecoverably damaged. 3. Once the voltage of the lowest cell has increased above 2.5V, increase the charge current to 0.1C. For a 100Ah battery, this is a charge current of 10A. 5. Make a note of the initial battery terminal voltage and battery cell voltages. 4. Connect the battery to a BMS and ensure that the BMS has control over the battery charger. 6. Start the charger. 7.

The BMS might turn the charger off, then on again for a short time and then off again. This can occur many times over and is normal behaviour in case of a significant cell imbalance. 8. Make a note of the voltages at regular intervals. 9. The cell voltages should increase during the first part of the charging process. If the voltage of any of the cells does not increase in the first half hour, consider the battery unrecoverable and abort the charging procedure. 10. Check the battery temperature at regular intervals. If you see a sharp increase in temperature, consider the battery unrecoverable and abort the charging procedure. 11.

Once the battery has reached 13.8V (27.6V, 55.2V), increase the charge voltage to 14.2V (28.4V, 56.8V) and increase the charge current to 0.5C. For a 100Ah battery, this is a charge current of 50A. 12. The cell voltages will increase more slowly; this is normal during the middle part of the charge process. 13. Leave the charger connected for 6 hours. 14. Check the cell voltages; they should all be within 0.1V of each other. If one or more cells have a much higher voltage difference, consider the battery damaged. 15. Let the battery rest for a few hours. 16. Check the voltage of the battery. It should comfortably sit above 12.8V (25.6V, 51.2V), like 13.2V (26.4V, 52.8V) or higher.

And the cell voltages should still be within 0.1V of each other. 17. Let the battery rest for 24 hours. 18. Measure the voltages again. If the battery voltage is below 12.8V (25.6V, 51.2V) or there is a noticeable cell imbalance, consider the battery damaged beyond recovery. Page 25 Troubleshooting & support