© Siemens AG 2010 Solid-State Switching Devices for Resistive Loads General data Overview 4 Function is available Function is possible 1) The converter can also be used with three-phase devices. -- Function not available. Benefits Characteristics • Considerable space savings thanks to a width of only 22.5 mm • Variety of connection methods:
Screw terminal, spring-type connection or ring terminal lug, there is no problem – they are all finger-safe • Flexible for all applications with function modules for retrofitting • Possibility of fuseless short-circuit proof design Advantages • Saves time and costs with fast mounting and commissioning, short start-up times and easy wiring • Extremely long life, low maintenance, rugged and reliable • Space-saving and safe thanks to side-by-side mounting up to an ambient temperature of +60 °C • Modular design:
Standardized function modules and heat sinks can be used in conjunction with solid-state relays to sat- isfy individual requirements • Safety due to lifelong, vibration-resistant and shock-resistant spring-type terminal connection method even under tough conditions 4/45 Siemens LV 1 · 2010 Type Solid-State Relays Solid-State Contactors Function modules Single-phase Three- phase Single- phase Three- phase Converters Load monitoring Heating current monitoring Power controllers Power regulators 22.5 mm 45 mm 45 mm Basic Extended Usage Simple use of exist- ❑ ing solid-state relays Complete unit ❑ "Ready to use" Space-saving ✓ Can be extended ✓ with modular func- tion modules Frequent switching -- and monitoring of loads and solid-state relays/solid-state contactors Monitoring of up to -- 6 partial loads Monitoring of more -- than 6 partial loads Control of the heat- -- ing power through an analog input Power control -- ❑ ✓ ❑ ❑ ❑ -- -- -- -- -- -- ❑ ❑ ✓ ✓ -- -- -- -- -- -- ✓ -- ✓ ✓ ✓ ✓ ✓ -- -- -- -- -- 1) ✓ 1) -- -- -- -- -- -- -- -- -- -- -- -- ✓ ✓ ✓ ✓ ✓ -- -- -- -- -- ✓ -- ✓ ✓ -- -- -- -- -- -- -- -- ✓ -- -- -- -- -- -- -- ✓ -- -- -- ✓ ✓ -- -- -- -- -- -- -- -- -- -- ✓ Startup Easy setting of set- -- point values with "Teach" button "Remote Teach" -- input for setting set- points -- -- -- -- -- -- ✓ ✓ -- ✓ ✓ -- -- -- -- -- -- -- ✓ -- -- Mounting Mounting onto -- mounting rails or mounting plates Can be snapped -- directly onto a solid- state relay or con- tactor For use with "Cool- ✓ plate" heat sink -- -- -- ✓ ✓ -- -- -- -- -- -- -- -- -- -- ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ -- -- -- -- -- -- -- -- Wiring Connection of load ✓ circuit as for con- trolgear Connection of load -- circuit from above ✓ -- ✓ ✓ ✓ -- ✓ ✓ ✓ ✓ ✓ ✓ -- -- -- -- -- -- -- -- --