Siemens — Siemens SIRIUS 3RW Soft Starters and Solid-State Switching Devices Manual

© Siemens AG 2010 Solid-State Switching Devices for Resistive Loads 3RF29 Function Modules SIRIUS load monitoring for 3RF Overview Application Load monitoring for 3RF2 single-phase solid-state switching devices The device is used for monitoring one or more loads (partial loads). The function module can only be used in conjunction with a 3RF21 solid-state relay or a 3RF23 solid-state contactor. The devices with spring-type connections in the load circuit are not suitable. Many faults can be quickly detected by monitoring a load circuit connected to the solid-state switching device, as made possible with this module.

Examples include the failure of load elements (up to 6 in the basic version or up to 12 in the extended version), alloyed power semiconductors, a lack of voltage or a break in a load circuit. A fault is indicated by one or more LEDs and re- ported to the controller by way of a PLC-compatible output. The principle of operation is based on permanent monitoring of the current intensity. This figure is continuously compared with the reference value stored once during start-up by the simple press of a button. In order to detect the failure of one of several loads, the current difference must be 1/6 (in the basic version) or 1/12 (in the extended version) of the reference value.

In the event of a fault, an output is actuated and one or more LEDs indicate the fault. 4 Selection and ordering data Rated control supply voltage 24 V DC Rated control supply voltage 24 V AC/DC Rated control supply voltage 110 V AC 20 110 … 230 A 1 1 unit 101 0.175 20 400 … 600 A 1 1 unit 101 0.175 50 110 … 230 A 1 1 unit 101 0.175 50 400 … 600 A 1 1 unit 101 0.175 90 110 … 230 A 1 1 unit 101 0.175 90 400 … 600 A 1 1 unit 101 0.175 4/69 Siemens LV 1 · 2010 * You can order this quantity or a multiple thereof. Rated operational Rated operational DT current Ie voltage Ue A V Order No. Price per PU PU PS* PG Weight (UNIT, per PU SET, M) approx. kg Weight per PU approx.

Basic load monitoring Rated operational current Ie Rated operational voltage Ue 6 -- A 20 -- A • With mounted 3RF29 00-0RA88 cover 6 -- A 20 -- A 3RF29 06-0FA08 1 1 unit 101 0.068 1 1 unit 101 0.068 1 1 unit 101 0.068 1 1 unit 101 0.068 3RF29 20-0FA08 3RF29 06-0FA08-0KH0 3RF29 20-0FA08-0KH0 Extended load monitoring 20 110 … 230 A 20 400 … 600 A 50 110 … 230 A 50 400 … 600 A 90 110 … 230 A 90 400 …

600 A 3RF29 20-0GA13 1 1 unit 101 0.175 1 1 unit 101 0.175 1 1 unit 101 0.175 1 1 unit 101 0.175 1 1 unit 101 0.175 1 1 unit 101 0.175 3RF29 20-0GA16 3RF29 50-0GA13 3RF29 50-0GA16 3RF29 90-0GA13 3RF29 90-0GA16 3RF29 20-0GA33 3RF29 20-0GA36 3RF29 50-0GA33 3RF29 50-0GA36 3RF29 90-0GA33 3RF29 90-0GA36 Version DT Order No. Price per PU PU PS* PG Weight (UNIT, per PU SET, M) approx. kg Weight per PU approx. Optional accessories 3RF29 00-0RA88 1 10 units 101 0.001 Sealable covers B for function modules (not for converters) 3RF29 00-0RA88 3RF29 00-0RA88