© Siemens AG 2010 Solid-State Switching Devices for Resistive Loads 3RF29 Function Modules SIRIUS heating current monitoring for 3RF Overview Special versions: deviations from the standard version Heating current monitoring for 3RF2 single-phase solid- state switching devices 3RF29 ..-0JA1.-1KK0 Many faults can be quickly detected by monitoring a load circuit connected to the solid-state switching device, as made possible with this module. Examples include the failure of up to 6 load el- ements, alloyed power semiconductors, a lack of voltage or a break in a load circuit. A fault is indicated by LEDs and reported to the controller by way of a relay output (NC contact).
If the current is below 50% of the lower teach current during the teach routine, the device will go into "Standby" mode; the LOAD LED will flicker. The device thus detects a non-connected load, e. g. channels not required for tool heaters, and does not signal a fault. This mode can be reset by re-teaching. Application The principle of operation is based on permanent monitoring of the current intensity. This figure is continuously compared with the reference value stored once during start-up. In order to de- tect the failure of one of several loads, the current difference must be 1/6 of the reference value. In the event of a fault, an out- put is actuated and the LEDs indicate the fault.
The device is used for monitoring one or more loads (partial loads). The function module can only be used in conjunction with a 3RF21 solid-state relay or a 3RF23 solid-state contactor. The devices with spring-type connections in the load circuit are not suitable. The heating current monitoring has a teach input and therefore differs from the load monitoring. This remote teaching function enables simple adjustment to changing loads without manual in- tervention. 4 Selection and ordering data Rated control supply voltage 24 V AC/DC 16 110 … 230 A 1 1 unit 101 0.175 16 110 … 230 A 1 1 unit 101 0.175 16 400 … 600 A 1 1 unit 101 0.175 32 110 … 230 A 1 1 unit 101 0.175 32 400 …
600 A 1 1 unit 101 0.175 32 400 … 600 A 1 1 unit 101 0.175 1) Supplied without control connector. The control connector can be pur- chased from Phoenix Contact by quoting Order No. 1982 790 (2.5 HC/6- ST-5.08). * You can order this quantity or a multiple thereof. 4/70 Siemens LV 1 · 2010 Rated operational Rated operational DT current Ie voltage Ue A V Order No. Price per PU PU PS* PG Weight (UNIT, per PU SET, M) approx. kg Weight per PU approx. Heating current monitoring1) Rated operational current Ie Rated operational voltage Ue 3RF29 16-0JA13 3RF29 16-0JA13-1KK0 3RF29 16-0JA16-1KK0 3RF29 32-0JA13-1KK0 3RF29 32-0JA16 3RF29 32-0JA16-1KK0 Version DT Order No.
Price per PU PU PS* PG Weight (UNIT, per PU SET, M) approx. kg Weight per PU approx. Optional accessories 3RF29 00-0RA88 1 10 units 101 0.001 Sealable covers B for function modules (not for converters) 3RF29 00-0RA88 3RF29 00-0RA88