Siemens — Siemens SIRIUS 3RW Soft Starters and Solid-State Switching Devices Manual

© Siemens AG 2010 Solid-State Switching Devices for Resistive Loads 3RF29 Function Modules SIRIUS power regulators for 3RF Overview Application Power regulators for 3RF2 single-phase solid-state switch- ing devices The power regulator can be used for: • Complex heating systems • Heating elements with temperature-dependent resistor • Heating elements with ageing after long-time service • Simple indirect control of temperature The power regulator is a function module for the autonomous power control of complex heating systems. The following functions have been integrated: • Power controller with proportional-action control for adjusting the power of the connected load.

Here, the setpoint value is set with a rotary knob on the module as a percentage with refer- ence to the 100 % power stored as a setpoint value. Changes in the mains voltage or in the load resistance are compensated in this case. • Inrush current limitation: With the aid of an adjustable voltage ramp, the inrush current is limited by means of phase control. This is useful above all with loads such as lamps which have an inrush transient current. • Load circuit monitoring for detecting load failure, alloyed power semiconductors, lack of voltage or a break in the load circuit. Part-load monitoring is not possible. Load fluctuations are compensated.

The power regulator can be used on the instantaneously switch- ing 3RF21 and 3RF23 solid-state switching devices (single- phase). If only the full-wave operating mode is used, the power regulator can also be used on the zero-point switching solid- state relays and contactors. The power regulator adjusts the power in the connected load by means of a solid-state switching device depending on the taught power and the selected setpoint. Changes in the mains voltage or in the load resistance are thus compensated by the power regulator. The setpoint value can be predefined externally as a 0 to 10 V signal or internally by means of a potentiometer.

Depend- ing on the setting of the potentiometer ( t R ), the adjustment is car- ried out according to the principle of full-wave control or gener- alized phase control. Power control 4 Full-wave control In this operating mode the output is adjusted to the required set- point value changing the on-to-off period. The period duration is predefined at one second. Generalized phase control In this operating mode the output is adjusted to the required set- point value by changing the current flow angle. In order to ob- serve the limit values of the conducted interference voltage for industrial networks, the load circuit must include a reactor with a rating of at least 200 μH.

Selection and ordering data Rated control supply voltage 24 V AC/DC Rated control supply voltage 110 V AC 20 110 … 230 A 1 1 unit 101 0.175 20 400 … 600 A 1 1 unit 101 0.175 50 110 … 230 A 1 1 unit 101 0.175 50 400 … 600 A 1 1 unit 101 0.175 90 110 … 230 A 1 1 unit 101 0.175 90 400 … 600 A 1 1 unit 101 0.175 * You can order this quantity or a multiple thereof. 4/72 Siemens LV 1 · 2010 Rated operational Rated operational DT current Ie voltage Ue A V Order No. Price per PU PU PS* PG Weight (UNIT, per PU SET, M) approx. kg Weight per PU approx. Power regulators Rated operational current Ie Rated operational voltage Ue 20 110 … 230 A 20 400 … 600 A 50 110 … 230 A 50 400 … 600 A 90 110 …

230 A 90 400 … 600 A 3RF29 20-0HA13 1 1 unit 101 0.175 1 1 unit 101 0.175 1 1 unit 101 0.175 1 1 unit 101 0.175 1 1 unit 101 0.175 1 1 unit 101 0.175 3RF29 20-0HA16 3RF29 50-0HA13 3RF29 50-0HA16 3RF29 90-0HA13 3RF29 90-0HA16 3RF29 20-0HA33 3RF29 20-0HA36 3RF29 50-0HA33 3RF29 50-0HA36 3RF29 90-0HA33 3RF29 90-0HA36 Version DT Order No. Price per PU PU PS* PG Weight (UNIT, per PU SET, M) approx. kg Weight per PU approx. Optional accessories 3RF29 00-0RA88 1 10 units 101 0.001 Sealable covers B for function modules (not for converters) 3RF29 00-0RA88 3RF29 00-0RA88