© Siemens AG 2010 BETA Measuring Three-Phase Measuring Devices 7KT1 31, 7KT1 34, 7KT1 35 multicounters More information Voltage measurement Readout data Depending on the selected connection type, the multicounter measures the delta voltages L1 against L2; L2 against L3 and L3 against L1 or the star voltages L1, L2, L3 against N. You can continuously display 6 measured quantities from the following 35 options: L symbol for the three-phase system This indicates that all physical units shown under this symbol are always 3 phase. L1 L1-N 1 L3-L1 l3 l1 L1-L2 3 N 2 L3-N L2-N l2 L2 L3 L2-L3 I2_08410b More information about multicounters can be found in Catalog ET B1 · 2010.
The current issue of the catalog can be downloaded from www.siemens.com/e-installation-catalogs . 19 2 set values are also indicated: 36 All the measured values are transmitted via LAN. 37 * You can order this quantity or a multiple thereof. 19/136 Siemens LV 1 · 2010 Ue V AC Ie Uc MW Order No. Price per PU PU PS* PG Weight per PU approx. Unit(s) Unit(s) kg Weight per PU approx. A AC V AC With PROFIBUS DP V0 interface Standard rail mounting For direct connection 3 × 230/400 63 230 6 B For transformer connection 5 ... 5000 A, adjustable in 5 A increments, secondary current 5 A 3 × 230/400 Trans- 230 6 B former /5 Front mounting For transformer connection 5 ...
5000 A, adjustable in 5 A increments, econdary current 5 A, mounting dimensions 96 mm × 96 mm 3 × 230/400 Trans- 230 -- B former /5 1 1 027 0.415 1 1 027 0.415 1 1 027 0.460 7KT1 350 7KT1 351 7KT1 352 No. Measured value Display Unit Assignment 1 2 3 4 5 6 Active power D1 W L1 Voltage D1 V L1 Current D1 A L1 Apparent power D1 VA L1 P.f. D1 P.f. L1 Voltage D1 V L1 – L2 7 8 9 10 11 12 Active power D2 W L2 Voltage D2 V L2 Current D2 A L2 Apparent power D2 VA L2 P.f. D2 P.f. L2 Voltage D2 V L2 – L3 13 14 15 16 17 18 Active power D3 W L3 Voltage D3 V L3 Current D3 A L3 Apparent power D3 VA L3 P.f. D3 P.f.
L3 Voltage D3 V L3 – L1 19 20 21 22 23 24 25 Temperatures D6 °C – Current, N conductor D6 A L Active power D4 W L reactive power D5 var L Apparent power D5 var L Frequency D6 Hz L P.f. D1, D2, D3, D6 P.f. L 26 27 28 29 30 31 32 33 34 35 Active energy tariff 1 D4 Wh L Active energy tariff 2 D4 Wh L Active energy tariff 1 D4 Wh L Active energy tariff 2 D4 Wh L Reactive energy tariff 1 D5 varh L, ind. Reactive energy tariff 2 D5 varh L, ind. Reactive energy tariff 1 D5 varh L, cap. Reactive energy tariff 2 D5 varh L, cap. Apparent energy tariff 1 D5 VAh L Apparent energy tariff 2 D5 VAh L Transformer setting D4 CT/A /5 Transformer setting D5 CT/A 5 ... 5000