© Siemens AG 2010 BETA Protecting Low-Voltage Fuse Systems 3NW cylindrical fuse systems More information Mounting Fuse holders size 8 mm Ч 32 mm and 10 mm Ч 38 mm have a sliding catch that enables the removal of individual devices from the assembly. Auxiliary switches Auxiliary switches are available for cylindrical fuse holders. These are simply clipped onto the base using the factory-fitted brackets. The infeed can be from the top or the bottom. Because the cylin- drical fuse holders are fitted with the same anti-slip terminals at the top and the bottom, the devices can also be bus-mounted at the top or the bottom. Sizes 8 mm Ч 32 mm and 10 mm Ч 38 mm:
The auxiliary switches support the remote display of the ON/OFF switching state of the fuse holder. Sizes 14 mm Ч 51 mm and 22 mm Ч 58 mm: The auxiliary switches support the remote display of fuse failure. However, fuse links with strikers are required for this function. When the fuse is tripped, a small striking pin - the striker - shoots out of the front of the fuse. Over an armature link in the auxiliary switch, the kinetic energy of this striker is used to switch a mini switch, which then initializes this signal over a floating contact. 19 * You can order this quantity or a multiple thereof. 19/78 Siemens LV 1 · 2010 Number of In For fuse links of MW DT poles size A mm × mm Order No.
Price per PU PU PS* PG Weight per PU approx. Unit(s) Unit(s) kg Weight per PU approx.
Without signal detector 1P 20 8 × 32 1 A 32 10 × 38 1 } 50 14 × 51 1.5 } 100 22 × 58 2 } 1P+N 20 8 × 32 1 A 32 10 × 38 1 } 50 14 × 51 3 B 100 22 × 58 4 B 2P 20 8 × 32 2 A 32 10 × 38 2 } 50 14 × 51 3 } 100 22 × 58 4 } 1 25 018 0.056 1 1/12 018 0.056 1 1 018 0.095 1 1 018 0.145 3NW7 313 3NW7 013 3NW7 111 3NW7 211 1 1 018 0.069 1 1 018 0.069 1 1 018 0.215 1 1 018 0.330 3NW7 353 3NW7 053 3NW7 151 3NW7 251 1 1 018 0.118 1 1/6 018 0.118 1 1 018 0.195 1 1 018 0.300 3NW7 323 3NW7 023 3NW7 121 3NW7 221 3P 20 8 ×32 3 A 32 10 × 38 3 } 50 14 × 51 4.5 } 100 22 × 58 6 } 3P+N 20 8 × 32 3 A 32 10 × 38 3 } 50 14 × 51 6 A 100 22 × 58 8 A 1 1 018 0.172 1 1/4 018 0.172 1 1 018 0.295 1 1 018 0.691 3NW7 333 3NW7 033 3NW7 131 3NW7 231 1 1 018 0.185 1 1 018 0.185 1 1 018 0.315 1 1 018 0.475 3NW7 363 3NW7 063 3NW7 161 3NW7 261 Auxiliary switches For indicating disconnection of the fuse link, solely for application of striker fuse links.
For retrofitting using the factory-fitted brackets. Contact: 250 V AC, 5 A Minimum contact load: 12 V, 25 mA For fuse bases 14 × 51 0.5 B For fuse bases 22 × 58 B For indicating the switching state of the fuse holder. For subsequent mounting with factory- fitted brackets. Contact: 230 V AC, 6 A/110 V DC, 1 A Minimum contact load: 12 V, 25 mA Terminals 1.5 mm² - 0.5 Nm For fuse holders 10 × 38 0.5 B 1 1 018 0.050 1 1 018 0.050 3NW7 901 3NW7 902 1 1 018 0.034 3NW7 903