Victron BMV-700H — 7.5.2. Backlight always on

Manual - BMV-700H 7.4.2. Low SoC alarm settings When enabled, the alarm will activate when the state of charge (SoC) falls below the set value for more than 10 seconds. The alarm will deactivate when the state of charge rises above the clear value 7.4.3. Low voltage alarm When enabled, the alarm will activate when the battery voltage falls below the set value for more than 10 seconds. The alarm will deactivate when the battery voltage rises above the clear value. When enabled, the alarm will activate when the battery voltage rises above the set value for more than 10 seconds. The alarm will deactivate when the battery voltage drops below the clear value. 7.4.4. High voltage alarm 7.5.

Display settings 7.5.1. Backlight intensity The intensity of the backlight This setting ranges from 0 (always off) to 9 (maximum intensity). 7.5.2. Backlight always on When set the backlight will not automatically turn off after 60 seconds of inactivity.

Page 29 All features and settings Setting Default Range Steps Set alarm value (setting 33) 1% 0 - 100% 1% Clear alarm value (setting 34) 1% 0 - 100% 1% Setting Default Range Steps Set alarm value (setting 35) 1.1V 0 - 95.0V 0.1V Set alarm value (setting 35) 0V 0 - 384V 0.1V Clear alarm value (setting 36) 1.0V 0 - 95.0V 0.1V Clear alarm value (setting 36) 0V 0 - 384V 0.1V Setting Default Range Steps Set alarm value (setting 37) 1.1V 0 - 95.0V 0.1V Set alarm value (setting 37) 0V 0 - 384V 0.1V Clear alarm value (setting 38) 1.0V 0 - 95.0V 0.1V Clear alarm value (setting 38) 0V 0 - 384V 0.1V Setting Default Range Step size Backlight intensity (setting 49) 5 0 - 9 1