Victron BMV-712 Smart — 7.5.2. Backlight always on

Manual - BMV-712 Smart 7.4.6. High starter voltage alarm This setting is only available if the Aux input has been set to “Starter battery”, see chapter Aux input [40] . When enabled, the alarm will activate when the starter battery voltage rises above the set value for more than 10 seconds and the alarm will deactivate when the starter battery voltage drops below the clear value. 7.4.7. High temperature alarm This setting is only available if the Aux input has been set to “temperature”, see chapter Aux input [40] . When enabled, the alarm will activate when the battery temperature rises above the set value for more than 10 seconds.

The alarm will deactivate when the battery temperature drops below the clear value. 7.4.8. Low temperature alarm This setting is only available if the Aux input has been set to “temperature”, see chapter Aux input [40] . When enabled, the alarm will activate when the battery temperature falls below the set value for more than 10 seconds. The alarm will deactivate when the battery temperature rises above the clear value. 7.4.9. Midpoint deviation alarm This setting is only available if the Aux input has been set to “Midpoint”; see chapter Aux input [40] . When enabled, the alarm will activate when the midpoint voltage deviation rises above the set value for more than 10 seconds.

The alarm will deactivate when the midpoint voltage deviation drops below the clear value. 7.5. Display settings 7.5.1. Backlight intensity The intensity of the backlight This setting ranges from 0 (always off) to 9 (maximum intensity). 7.5.2. Backlight always on When set the backlight will not automatically turn off after 60 seconds of inactivity.

Page 36 All features and settings Setting Default Range Steps Set alarm value (setting 41) 1.1 V 0 - 95.0V 0.1V Clear alarm value (setting 42) 1.0 V 0 - 95.0V 0.1V Setting Default Range Step size Set relay value (setting 43) 0°C 0°F -40 - +99°C -40 - +210°F 1°C 1°F Clear relay value (setting 44) 0°C 0°F -40 - +99°C -40 - +210°F 1°C 1°F Setting Default Range Step size Set relay value (setting 45) 0°C 0°F -40 - +99°C -40 - +210°F 1°C 1°F Clear relay value (setting 46) 0°C 0°F -40 - +99°C -40 - +210°F 1°C 1°F Setting Default Range Steps Set alarm value (setting 47) 2 % 0 - 99 % 1 % Clear alarm value (setting 48) 1 % 0 - 99 % 1 % Setting Default Range Step size Backlight intensity (setting 49) 5 0 - 9 1