Victron BMV-712 Smart — 7.4.5. Low starter voltage alarm

Manual - BMV-712 Smart When disabled (set to OFF) the buzzer will not sound an alarm. 7.4.2. Low SoC alarm settings When enabled, the alarm will activate when the state of charge (SoC) falls below the set value for more than 10 seconds. The alarm will deactivate when the state of charge rises above the clear value 7.4.3. Low voltage alarm When enabled, the alarm will activate when the battery voltage falls below the set value for more than 10 seconds. The alarm will deactivate when the battery voltage rises above the clear value. 7.4.4. High voltage alarm When enabled, the alarm will activate when the battery voltage rises above the set value for more than 10 seconds.

The alarm will deactivate when the battery voltage drops below the clear value. 7.4.5. Low starter voltage alarm This setting is only available if the Aux input has been set to “Starter battery”, see chapter Aux input [40] . When enabled, the alarm will activate when the starter battery voltage falls below the set value for more than 10 seconds. The alarm will deactivate when the starter battery voltage rises above the clear value.

Page 35 All features and settings Setting Default Modes Alarm buzzer (setting 32) ON ON OFF Setting Default Range Steps Set alarm value (setting 33) 1% 0 - 100% 1% Clear alarm value (setting 34) 1% 0 - 100% 1% Setting Default Range Steps Set alarm value (setting 35) 1.1V 0 - 95.0V 0.1V Clear alarm value (setting 36) 1.0V 0 - 95.0V 0.1V Setting Default Range Steps Set alarm value (setting 37) 1.1V 0 - 95.0V 0.1V Clear alarm value (setting 38) 1.0V 0 - 95.0V 0.1V Setting Default Range Steps Set alarm value (setting 39) 1.1V 0 - 95.0V 0.1V Clear alarm value (setting 40) 1.0V 0 - 95.0V 0.1V