Manual - BMV-712 Smart 7.6.5. Shunt current When a shunt other than the one supplied with the battery monitor is used, use this setting to set the rated current of the shunt. 7.6.6. Shunt voltage When a shunt other than the one supplied with the battery monitor is used, use this setting to change the rated voltage of the shunt. 7.6.7. Temperature unit This setting is available if the aux input has been set to "Temperature", see the Aux input [40] setting. Use this setting to select the temperature unit the battery monitor head unit is using. Note that this setting only affects the battery monitor head unit display and settings.
To change the temperature unit in the VictronConnect app see Temperature unit setting [42] . 7.6.8. Temperature coefficient This setting is available if the aux input has been set to "Temperature", see the Aux input [40] setting. The available battery capacity decreases with temperature. The temperature coefficient (delta T) is the percentage the battery capacity changes with temperature when temperature decreases to less than 20°C (above 20°C the influence of temperature on capacity is relatively low and is not taken into account). Typically, the reduction, compared to the capacity at 20°C, is 18% at 0°C and 40% at -20°C.
The unit of this value is “%cap/°C” or per cent capacity per degree Celsius. The typical value (below 20°C) is 1%cap/°C for lead acid batteries, and 0.5%cap/°C for LFP batteries. 7.6.9. Aux input This setting sets the function of the auxiliary input. Select between: None, Starter battery, Midpoint or Temperature. Note that if the battery monitor settings are accessed via the head unit, this setting will be part of the miscellaneous setting, and if accessed via VictronConnect it will be part of the battery settings. 7.6.10. Battery starts synchronised For full information about this setting see the Battery SOC on reset [30] chapter.
Page 40 All features and settings Setting Default Range Step size Shunt current (setting 65) 500A 1 - 9999A 1A Setting Default Range Step size Shunt voltage (setting 66) 50mV 1 - 75mV 1mV Setting Default Modes Temperature unit (setting 67) CELC CELC/FAHR Setting Default Range Step size Temperature coefficient (setting 68) 0.0%cap/°C 0.0%cap/°F 0 - 2.0%cap/°C 0 - 3.6%cap/°F 0.1%cap/°C 0.1%cap/°F Setting Default Modes Description NONE Disables the auxiliary input. Aux input (setting 69) NONE START Auxiliary voltage, e.g. a starter battery MID Midpoint voltage TEMP Battery temperature. Note that a special temperature sensor is needed. For more information see:
Auxiliary connection for temperature monitoring [9]