Victron BMV-712 Smart — 7.7. Additional settings

Manual - BMV-712 Smart Determines whether to enable Bluetooth. If turned OFF using the VictronConnect app, the Bluetooth functionality is not disabled until disconnected from the BMV. 7.6.11. Bluetooth mode 7.6.12. Monitor Mode Setting 72 If you wish to use the battery monitor to monitor individual DC circuits rather than as a whole-of-system battery monitor, you can change the "Monitor mode" setting in the "Misc" menu from "Battery Monitor" to "DC Energy Meter". If "DC meter" is selected, you can select the following types:

Solar charger, Wind charger, Shaft generator, Alternator, Fuel cell, Water generator, DC-DC charger, AC charger, Generic source, Generic load, Electric drive, Fridge, Water pump, Bilge pump, DC system, Inverter, Water heater. When connected to a GX device, the type, the current and the power is shown in the user interface, and this information is also available on the VRM Portal. When the GX device is also configured as type “has DC System”, the GX does more than just recording and visualisation: 1. The power shown in the DC system box is the sum of power reported by all battery monitors configured as such.

Having multiple meters can be useful, for example, in a catamaran, so that the DC systems in the port hull and in the starboard hull are being measured. 2. The DC system current is being compensated for when setting DVCC charge current limits to inverter/chargers and solar chargers. For example, when a load of 50A is being measured, and CCL by the battery is 25A, the limit given to the inverter/charger or solar charger is 75A. See the GX device documentation for more information about these advanced features, especially refer to the Distributed voltage and current control chapter. 7.6.13.

Current measurement direction The current-measurement direction setting allows you to choose on which side of the shunt the battery (or battery bank) is connected. This ensures that current-flow calculations use the correct polarity. Reversed mode (on): the battery negative is connected to the shunt’s load terminal. Normal mode (off): the battery negative is connected to the shunt’s battery terminal. This setting was introduced in firmware version v4.19 and is not supported in earlier versions. This setting is protected by the "Settings Lock" feature (so if the settings are locked, this setting cannot be changed). 7.7.

Additional settings These VictronConnect settings are not located in the VictronConnect settings menu but are located elsewhere in the VictronConnect app. Page 41 All features and settings Setting Default Modes Start synchronized (setting 70) ON ON/OFF Setting Default Modes Bluetooth mode (setting 71) ON ON/OFF VictronConnect app setting Default setting Modes Current measurement direction Normal Normal Reversed BMV display setting Default setting Modes Reverse shunt direction (setting 76) off off on