177 MG.50.A4.50 -VLT является зарегистрированной торговой маркой Danfoss VLT cåðèè 5000 PNU Parameter Factory setting Range Online 4-Setup Conversion Data # description index type 400 Brake function/overvoltage contr ol Off Yes 0 No5 401 Brake resistor, ohm Depends on the unit Yes No -1 6 402 Brake power limit, kW Depends on the unit Yes No 2 6 403 Power monitoring On Yes No 0 5 404 Brake check Off Yes No 0 5 405 Reset function Manual reset Yes Yes 0 5 406 Automatic restart time 5 sec. 0 - 10 sec. Yes Yes 0 5 407 Mains Failure No function Yes Yes 0 5 408 Quick discharge Not possible Yes Yes 0 5 409 Trip delay torque Off 0 - 60 sec.

Yes Yes 0 5 410 Trip delay-inverter Depends on type of unit 0 - 35 sec. Yes Yes 0 5 411 Switching frequency Depends on type of unit 3 - 14 kHz Yes Yes 2 6 412 Output frequency dependent switching frequency Not possible Yes Yes 0 5 413 Overmodulation function On Yes Yes -1 5 414 Minimum feedback 0.000 -100,000.000 - FB HIGH Yes Yes -3 4 415 Maximum feedback 1500.000 FB - 100,000.000 LOW Yes Yes -3 4 416 Process unit % Yes Yes 0 5 417 Speed PID proportional gain 0.015 0.000 - 0.150 Yes Yes -3 6 418 Speed PID integration time 8 ms 2.00 - 999.99 ms Yes Yes -4 7 419 Speed PID differentiation time 30 ms 0.00 - 200.00 ms Yes Yes -4 6 420 Speed PID diff.

gain ratio 5.0 5.0 - 50.0 Yes Yes -1 6 421 Speed PID low-pass filter 10 ms 5 - 200 ms Yes Yes -4 6 422 U 0 voltage at 0 Hz 20.0 V 0.0 - parameter 103 Yes Yes -1 6 423 U 1 voltage parameter 103 0.0 - U VLT, MAX Yes Yes -1 6 424 F 1 frequency parameter 104 0.0 - parameter 426 Yes Yes -1 6 425 U 2 voltage parameter 103 0.0 - U VLT, MAX Yes Yes -1 6 426 F 2 frequency parameter 104 par.424-par.428 Yes Yes -1 6 427 U 3 voltage parameter 103 0.0 - U VLT, MAX Yes Yes -1 6 428 F 3 frequency parameter 104 par.426 -par.430 Yes Yes -1 6 429 U 4 voltage parameter 103 0.0 - U VLT, MAX Yes Yes -1 6 430 F 4 frequency parameter 104 par.426-par.432 Yes Yes -1 6 431 U 5 voltage parameter 103 0.0 - U VLT, MAX Yes Yes -1 6 432 F 5 frequency parameter 104 par.426 - 1000 Hz Yes Yes -1 6 433 Torque proportional gain 100% 0 (OFF) - 500% Yes Yes 0 6 434 Torque integral time 0.02 sec.

0.002 - 2.000 sec. Yes Yes -3 7 437 Process PID Normal/inverse control Normal Yes Yes 0 5 438 Process PID anti windup On Yes Yes 0 5 439 Process PID start frequency parameter 201 f - f MIN MAX Yes Yes -1 6 440 Process PID proportional gain 0.01 0.00 - 10.00 Yes Yes 0 6 441 Process PID integral time 9999.99 sec. (OFF) 0.01 - 9999.99 sec. Yes Yes 4 7 442 Process PID differentiation time 0.00 sec. (OFF) 0.00 - 10.00 sec. Yes Yes 4 6 443 Process PID diff.

gain limit 5.0 5.0 - 50.0 Yes Yes 0 6 444 Process PID lowpass filter time 0.01 0.01 - 10.00 Yes Yes 4 6 445 Flying start Disable Yes Yes 0 5 446 Switching pattern Automatic Yes Yes 0 5 447 Torque compensation 100% -100 - +100% Yes Yes 0 3 448 Gear ratio 1 0.001 - 100.000 No Yes -3 4 449 Friction loss 0% 0 - 50% No Yes -2 6