omron — PMAC Quick Reference

PMAC Quick Reference Guide APPENDIX B – PMAC I-VARIABLES SUMMARY Appendix B – PMAC I-Variables Summary 75 Global I-Variables Range Default Units I1 Serial Handshake Line Disable 0 .. 3 0 None I2 Control Panel Disable 0 .. 3 1 None I3 I/O Handshake Mode 0 .. 3 1 None I4 Communications Checksum Enable 0 .. 3 0 None I5 PLC Programs On/Off 0 .. 3 0 None I6 Error Reporting Mode 0 .. 3 3 None I7 In-Position # of Consecutive Cycles 0 .. 255 0 Background computation cycles (minus one) I8 Real Time Interrupt Period 0 .. 255 2 Servo Interrupt Cycles I9 Full/Abbrev. Listing Form 0 .. 3 2 None I10 Servo Interrupt Time 0 .. 8,388,607 3713707 1 / 8,388,608 msec I11 Program Move Calc. Time 0 ..

8,388,607 0 Msec I12 Jog-to-Pos. Calc. Time 1 .. 8,388,607 10 Msec I13 Programmed Move Segmentation Time 0 .. 8,388,607 0 Msec I14 Auto Position Match On Run Enable 0 .. 1 1 None I15 Deg/Radians for User Trig 0 .. 1 0 (degrees) None I16 Rotary Buffer Request On Point 0 .. 8,388,607 5 Command lines. I17 Rotary Buffer Request Off Point 0 .. 8,388,607 10 Program lines I18 Fixed Buffer Full Warning Point 0 .. 8,388,607 10 Long Memory Words Data Gathering I-Variables Range Default Units I19 Data Gathering Period (In Servo Cycles) 0 .. 8,388,607 1 Servo Interrupt Cycles I20 Data Gathering Selection Mask $000000 .. $FFFFFF $0 None I21 Data Gathering Source 1 Address $000000 ..

$FFFFFF $0 Modified PMAC addresses I22- I44 Data Gathering Source 2 thru 24 Addresses $000000 .. $FFFFFF $0 Modified PMAC addresses I45 Data Gathering Buffer Location And Mode 0 .. 3 0 None