omron — PMAC Quick Reference

PMAC Quick Reference Guide 86 Troubleshooting PASSWORD={string } Enter/set program password PASSWORD={string} PC Report program counter PC PE Report program execution pointer PE PMATCH Re-match axis positions to motor positions PMATCH PR Report rotary program remaining PR Q Quit program at end of move Q Q{constant} Report Q-Variable value Q{constant}[..{constant}] Q{constant}={exp ression} Q-Variable value assignment Q{constant}[..{constant}] ={expression} R Run motion program R R[H]{address} Report the contents of a specified memory addresses R[H]{address} [,{constant}] RESUME PLC Resume execution of specified PLC programs RESUME PLC {constant}[,{constant}...] RES PLC {constant}[,{constant}...] S Execute one move step of motion program S SAVE Copy setup parameters to non-volatile memory SAVE SIZE Report the amount of unused buffer memory in PMAC SIZE TYPE Report type of PMAC TYPE UNDEFINE Erase coordinate system definition UNDEFINE UNDEF UNDEFINE ALL Erase coordinate definitions in all coordinate systems UNDEFINE ALL UNDEF ALL V Report motor velocity V VERSION Report PROM firmware version number VERSION VER W{address} Write value(s) to a specified addresses W{address},{value} [,{value}...] Z Make commanded axis positions zero Z