Downloaded from https://www.everyspec.com MIL-STD-1311D 1. Low-pass filter (a) is an optional device which is suggested for initial evaluation to determine whether the attenuation of spurious or harmonic signals is required. If it is determined that these unwanted signals are negligible, then the low-pass filter can be considered as an optional device and its use can be omitted. If it is determined that these unwanted signals have an effect on the overall tube performance, then the low-pass filter shall be used. In general, the harmonic energy is negligible compared to the fundamental and, thus, low-pass filters are normally not required.
Occasionally, couplers or voltage probes will couple more tightly to harmonic signals than the fundamental and, in these instances, a low-pass filter is recommended. Where it may not be practical to obtain a high-power low-pass filter for some high-power applications. It is then permissible to insert a lower-power filter (in the energy sampling region) between the directional coupler and the output indicating device as shown in the reflectometer system (e). In some high-power equipment, the detector is built into the directional coupler loop, providing no access for a low-pass filter. In such a case, a spectrum analyzer in conjunction with calorimetric techniques can be used. 2.
The frequency can be measured either in the driver or preferably in the output side as indicated in the circuit block diagram. To measure the frequency either of the following devices and methods may be used: A coupler (b) with a suitable resistance attenuator (c) are necessary to prevent burn-out of the frequency meter (d) due to excessive power coupling. Only the coupler needs to be in series with the driver system. A portable frequency instrument (d') may be periodically coupled to the rf system through the sensing of radiated energy.
After the frequency has been established, the frequency measuring instrument and/or attenuators may be removed to avoid tying up of an expensive frequency instrument on a permanent basis. A portable frequency instrument, however, should be made readily available to periodically check and verify the frequency specified. The instrument used for measuring the frequency should either have an accuracy of ± 1.0 percent or meet the frequency tolerances specified in the TSS. 3.
A reflectometer system (e) consisting of a one-port forward directional coupler and a one-port reverse directional coupler, its counterpart, a two-port directional coupler, or a one-port directional coupler with a bi-directional rotating plug- in element, any of which are connected to associated readout instrumentation calibrated for either power output or VSWR. These directional couplers are usually connected to an output indicating device or readout device such as a crystal detector or a bolometer detector.
In the case where the sampling power level is excessive for crystal or bolometer detectors, the directional coupler can be directly coupled to a calorimetric load and its associated power meter. The directional coupler (f) and output indicating device are necessary units for measuring the true power (forward minus reverse power) of driver input or output. In the instance where the load matches the transmission line, the net power is equal to the forward power since the reverse power is negligible or zero.
The reflectometer system (e), depending upon the output readout indicating device, can be used to measure either true power output (forward minus reverse power) or voltage standing wave ratio (VSWR). Where the true power of the transmission system is measured, the VSWR can be calculated by using the relationship: The converse is equally true if VSWR is measured. The true power (Pt) can then be calculated by using the same equation and the Pt = Pi - Pr relationship. 4. The components (h), (i), and (j) represent the input, TUT and output circuits of the power amplifier system. 5. A load (k) providing for a matched dissipative termination absorbs the rf output power of the amplifier system.
The correct power dissipated in the load can also be measured calorimetrically. When power is measured calorimetrically, the use of the reflectometer system (directional coupler and output indicating device) is optional. 1 1 Pr + = r r Pi 2 where r = VSWR Pr = reflected power Pi = incident or forward power Pt = true power = Pi - Pr FIGURE 2214-2. Schematic for power amplifier - Continued. METHOD 2214B 2214-4 19 September 1973