Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D RESONANT FREQUENCY METHOD 2220 (Obsolescent) NOTE: This test is normally performed as a "Qualification only" test. 1. Purpose. The purpose of this test is to determine the tube's ability to resonate at a specified frequency. 2. Equipment. a. Lecher frame. b. Oscillator (or signal generator) loosely coupled to the Lecher frame. c. Grid current meter (or auxiliary Lecher line with voltage detector). NOTE: Drawing 244-JAN indicates 900-MHz resonant frequency test equipment for subminiature tubes. 3. Procedure. a. Connect the nonoperating tube to the open end of the Lecher frame.

The specified pins shall be attached to the Lecher wires (lines) or rods. The diameter and spacing of the Lecher wires (lines) or rods shall be as specified on the TSS. b. The oscillator shall be tuned to the frequency specified. 4. Measurements. At resonance, the distance between the base of the TUT and the Lecher frame shunt shall be not less than the specified minimum limit. METHOD 2220 2220-1 19 April 1968