Downloaded from https://www.everyspec.com MIL-STD-1311D IONIZATION CHARACTERISTICS METHOD 3201 (Thyratron, Gas) Limits specified for grid voltage shall apply when the common point of the anode and grid circuits is the cathode, or, in filamentary types, is the midtap of the filament transformer or the midpoint of the filament, if present. 1. Critical grid voltage for conduction. Under the conditions specified, the control-grid voltage shall be changed in a positive direction until the tube starts to conduct current. The grid voltage measured at the grid-voltage supply required to cause conduction shall be within the limit(s) specified. 2. Critical anode voltage for conduction.
Under the conditions specified on the TSS, the anode voltage shall be increased until the tube starts to conduct current. The anode voltage required shall be within the limit(s) specified. METHOD 3201 3201-1 19 April 1968