Downloaded from https://www.everyspec.com MIL-STD-1311D HEATER CURRENT METHOD 3241 (Thyratron) 1. Heater current (cathode). 1.1 Nonreservoir type. With the specified voltage applied to the heater, the resulting current, after equilibrium temperature is reached, shall be within the limit(s) specified. During this test, no other element shall be conducting. 1.2 Reservoir type. With the specified voltage applied to the heater terminals of a tube having an internally connected reservoir, the resulting current after equilibrium temperature is reached, shall be within the limit(s) specified.
If the tube has an adjustable reservoir, the test shall be performed with the reservoir voltage set as specified under the particular or general test conditions. During this test no other element shall be conducting. 2. Heater current (reservoir). With the cathode-heater voltage set as specified and the specified voltage applied to the reservoir heater, the resulting reservoir-heater current, after equilibrium temperature is reached, shall be within the limit(s) specified. During this test no other element shall be conducting. METHOD 3241 3241-1 19 April 1968